Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360
android app
/
iOS App/ web portal.
{
"products": [
{
"_id": "5cc196f72f1016000190112e",
"fptag": "JANANIENTERPRISES",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "HEAT EXCHANGER & PLATE HEAT EXCHANGER",
"description": "HEAT EXCHANGER & PLATE HEAT EXCHANGER\n\nFunction of Plate Heat Exchangers\n\nThe plates are fitted with a gasket which seals the channel and directs the fluids into alternate channels. The number and size of the plates are determined by the flow rate, physical properties of the fluids, pressure drop and temperature program. The plate corrugations promote fluid turbulence and support the plates against differential pressure. The plates and the pressure plate are suspended from an upper carrying bar and located by a lower guiding bar both of which are fixed to the support columns.\n\nConnections are located in the frame cover, or if either or both fluids make more than a single pass within the unit, the frame and pressure plates. We are in the process of developing the Plate Heat Exchanger and would take up the manufacturing in the near future.\n\nThe plate heat exchanger consists of a pack of corrugated metal plates with portholes for the passage of the two fluids between which heat transfer will take place. The plate pack is assembled between a frame plate and a pressure plate and compressed by tightening bolts.\n\nApplications\n\nLube Oil Coolers\nSteam Heaters\nJacket Water Coolers\nWater Heaters (non-electrical)\nFuel Oil Heaters\nGearbox Oil coolers\n\nEquivalent to other Heat Exchangers\n\nIf you are unhappy with the original design of plate heat exchangers, send us the operating specifications and improvements required and we will offer a suitable replacement heatexchangers. We can also provide a shell and tube equivalent, if you would prefer to have a unit that is more easily repaired on our factory",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"plate pack",
"frame plate",
"pressure drop",
"pressure plates",
"original design",
"fluid turbulence",
"plate corrugations",
"alternate channels",
"temperature program",
"physical properties",
"plate heat exchangers",
"differential pressure",
"corrugated metal plates",
"suitable replacement heatexchangers"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 20,
"imageuri": "https://productimages.withfloats.com/actual/5cc196f7a3658d0001c5d2b1.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/5cc196f7a3658d0001c5d2b1.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2019-04-25T11:16:07.012Z",
"updatedon": "2019-04-25T11:16:07.012Z",
"buyonlinelink": null,
"producturl": "http://WWW.CHILLERCOOLINGTOWER.COM/products/heat-exchanger-plate-heat-exchanger/20",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "HEAT EXCHANGER & PLATE HEAT EXCHANGER",
"tags": [
"HEAT EXCHANGER & PLATE HEAT EXCHANGER"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "None",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5cc19c58d4443e000114a3e7",
"fptag": "JANANIENTERPRISES",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "PVDF / PFA Lined Pump",
"description": "PVDF / PFA Lined Pump\n\nSalient Features\n\n Volute & Impellers are injection molded PVDF material with smooth hydraulic passage.\nShaft are available with sleeves of different materials compatible with the liquid handfed\nPumps are available with externally mounted balanced mech seal or teflon gland packing or Internal mech seal with elastomer bellows.\n Less space required & easy to handle\n Excellent mechanical properties over a wide range of temperature (23°C to 130° C) . Abrasion resistance comparable to that of Polyamide, and relatively low coefficient of friction.\nSmooth running and long service life of the mechanical seal.\nEpoxy paint to protect from external protection of pump.\nExternal cooling arrangement provided in pump for enhancement of mechanical seal life.\nLiquid Handled\nPolypropylene can handle more than 560 types of chemicals Like Ammonium Chloride I Pickling, Con. HCL Acid, Calcium Sulphate, Caustic Soda, Cynic Acid, Ferric Nitrate, Phosphoric Acid and many more\nLiquid Handled\nPolypropylene can handle more than 560 types of chemicals Like Ammonium Chloride I Pickling, Con. HCL Acid, Calcium Sulphate, Caustic Soda, Cynic Acid, Ferric Nitrate, Phosphoric Acid and many more\nCapacity\tupto 190m3/hr\nHead\tupto 51 meters\nPower\tupto 55HP\nMax liquid temp\t130°C\nMax working pressure\t7kg/cm2\nRPM\t2900/1440\nSolid %\tMax 30%\nSolid Size\tMax 3mm",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"Cynic Acid",
"Ferric Nitrate",
"Phosphoric Acid",
"mechanical seal",
"low coefficient",
"Calcium Sulphate",
"Ammonium Chloride",
"long service life",
"balanced mech seal",
"Internal mech seal",
"external protection",
"cooling arrangement",
"Abrasion resistance comparable",
"different materials compatible",
"Excellent mechanical properties"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 25,
"imageuri": "https://productimages.withfloats.com/actual/5cc19c5836813b000121e74c.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/5cc19c5836813b000121e74c.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2019-04-25T11:39:04.488Z",
"updatedon": "2019-04-25T11:39:04.488Z",
"buyonlinelink": null,
"producturl": "http://WWW.CHILLERCOOLINGTOWER.COM/products/pvdf-pfa-lined-pump/25",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "PVDF / PFA Lined Pump",
"tags": [
"PVDF / PFA Lined Pump"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "None",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5cc19058b40f070001c70107",
"fptag": "JANANIENTERPRISES",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "EVAPORATOR COIL COOLER",
"description": "EVAPORATOR COIL COOLER\n\nFin Type Cooler are produced in forced draught and induced draught designs, and in single and multi-fan arrangements, depending customer specifications and requirements, We are the professional Fin Type Coolerand air cooled condenser manufacturers, tubes in copper and fins are aluminium MOC we use 5/8\" or 3/8\"and 1\" OD copper tubes as per customer specification, all tubes are well expanded tested for pressure and leak.\n\nFunction of Fin Fan Coolers\n\nAir Cooled Heat Exchangers - also known as Fin Fan Coolers, are heat transfer devices for rejecting heat from a hot process fluids such as refinery products or steam directly, to the surrounding atmosphere.\nJanani Enterprises Fin Fan Coolers are basically that multiple rows of fin tubes with a fan to move lower temperature ambient air over the coils in order to cool the hotter fluid, just like a radiator in industrial an automobile. An industrial example is a unit large enough to reject the heat from a turbine exhaust steam condensation system\n\nAdvantages of Fin Type Cooler\n\nA great deal of water gets preserved on using Fin Type Cooler.\nLess or no preparation needed as atmospheric air is in abundance\nNo formation of scale or heat exchanger cleaning is required\nThere are no mobile parts except for the fan and the motors. Hence the Cooling Tower maintenance is negligible\nDust, fly ash, living organisms or dirt do not get mixed up with process water\nThere are no constraints placed on the location of plant\nNo corrosions caused by air\nThis Cooling Tower performance ensures minimal environmental impact\nReduced annual operating expenses",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"hot process fluids",
"industrial example",
"heat transfer devices",
"minimal environmental",
"EVAPORATOR COIL COOLER",
"temperature ambient air",
"heat exchanger cleaning",
"customer specifications",
"Cooling Tower performance",
"Cooling Tower maintenance",
"annual operating expenses",
"Enterprises Fin Fan Coolers",
"turbine exhaust steam condensation",
"professional Fin Type Coolerand air"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 17,
"imageuri": "https://productimages.withfloats.com/actual/5cc19058285d930001412dad.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/5cc19058285d930001412dad.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2019-04-25T10:47:52.295Z",
"updatedon": "2019-04-25T10:47:52.295Z",
"buyonlinelink": null,
"producturl": "http://WWW.CHILLERCOOLINGTOWER.COM/products/evaporator-coil-cooler/17",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "EVAPORATOR COIL COOLER",
"tags": [
"EVAPORATOR COIL COOLER"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "None",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5cc18e082f101600019010b4",
"fptag": "JANANIENTERPRISES",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "INDUSTRIAL CHILLER - AIR COOLED CHILLER",
"description": "INDUSTRIAL CHILLER - AIR COOLED CHILLER\n\nChilled water is used to cool and dehumidify air in mid to large size commercial, industrial facilities like Water chillers can be either water cooled chiller or air cooled chiller Whenever a chiller's heat rejection can be used for a productive purpose, in addition to the cooling function.\n\nWater Cooled Chillers :\nWater cooled chillers are typically indoor installation and operation, it's all cooled by a separate condenser water loop and connected to outdoor Cooling Towers to expel heat to the atmosphere.\nAir Cooled Chiller:\nAir Cooled chillers are intended for outdoor installation and operation. Air cooled machines are directly cooled by ambient air being mechanically circulated directly through the machine's condenser coil to expel heat to the atmosphere.\nQuality Control:\nOur chillers are compact design covering minimum floor area. low cost maintenance, break through technology and long life serviceability Chilled water temperature can range from 5째C to 7째C Our Chillers manufacturing range from 0.5 TR to 250 TR\nIndustry Chiller Application\nPlastic industry in injection and blow moulding,\nMetal working cutting oils, welding equipment,\nDie-casting and machine tooling, chemical processing,\nPharmaceutical formulation,\nFood and beverage processing\n\nSpecifications\n\nSource of power\nChiller rating\nCapacity of the evaporator and condenser\nCooling capacity of the chiller\nType of the evaporator\nAmbient temperature\n \nFunction Of Industrial Chiller\nThe industrial chillers are normally packaged, complete and closed-loop systems Include the condenser, pumps, chiller, temperature control systems and associated valves.\nCirculates water or any other coolant at constant pressure and temperature. The coolant flows from the chiller to the point of application and back again.\nRefrigeration is used as the cooling process in most of the industrial chillers. Some depend on air or water that flows over the coils containing a specific coolant in order to regulate the temperature.\nThe coolant that is used most commonly in process chillers is water, though coolant mixtures are employed frequently. The latest development in industrial water chillers is the utilization of water cooling rather than air cooling.\nThe condenser cools the refrigerant with water and not air. A Cooling Tower cools the air, thus reducing the need for energy as well as the chiller size. This is because of the condenser's small surface area and the lack of cooling fans which minimizes the noise levels too.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"water cooling",
"Cooled chillers",
"process chillers",
"chiller Whenever",
"AIR COOLED CHILLER",
"industrial chillers",
"outdoor installation",
"industrial facilities",
"large size commercial",
"outdoor Cooling Towers",
"industrial water chillers",
"temperature control systems",
"separate condenser water loop",
"long life serviceability Chilled water temperature"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 13,
"imageuri": "https://productimages.withfloats.com/actual/5cc18e09b2b7610001df4e77.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/5cc18e09b2b7610001df4e77.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2019-04-25T10:38:00.9Z",
"updatedon": "2019-04-25T10:38:00.9Z",
"buyonlinelink": null,
"producturl": "http://WWW.CHILLERCOOLINGTOWER.COM/products/industrial-chiller-air-cooled-chiller/13",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "INDUSTRIAL CHILLER - AIR COOLED CHILLER",
"tags": [
"INDUSTRIAL CHILLER - AIR COOLED CHILLER"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "None",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5cc18b122f10160001901070",
"fptag": "JANANIENTERPRISES",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "EVAPORATIVE COIL COOLING TOWER",
"description": "EVAPORATOR COIL COOLING TOWER\n\nFin Type Cooler are produced in forced draught and induced draught designs, and in single and multi-fan arrangements, depending customer specifications and requirements, We are the professional Fin Type Coolerand air cooled condenser manufacturers, tubes in copper and fins are aluminium MOC we use 5/8\" or 3/8\"and 1\" OD copper tubes as per customer specification, all tubes are well expanded tested for pressure and leak.\n\nFunction of Fin Fan Coolers\n\nAir Cooled Heat Exchangers - also known as Fin Fan Coolers, are heat transfer devices for rejecting heat from a hot process fluids such as refinery products or steam directly, to the surrounding atmosphere.\nJanani Enterprises Fin Fan Coolers are basically that multiple rows of fin tubes with a fan to move lower temperature ambient air over the coils in order to cool the hotter fluid, just like a radiator in industrial an automobile. An industrial example is a unit large enough to reject the heat from a turbine exhaust steam condensation system\n\nAdvantages of Fin Type Cooler\nA great deal of water gets preserved on using Fin Type Cooler.\nLess or no preparation needed as atmospheric air is in abundance\nNo formation of scale or heat exchanger cleaning is required\nThere are no mobile parts except for the fan and the motors. Hence the Cooling Tower maintenance is negligible\nDust, fly ash, living organisms or dirt do not get mixed up with process water\nThere are no constraints placed on the location of plant\nNo corrosions caused by air\nThis Cooling Tower performance ensures minimal environmental impact\nReduced annual operating expenses\n\nApplications\n\nPredominantly used for air compressor and power generating units for applications of engine water cooling. Petroleum plant, power utility, steel manufacturing industry, cement, sugar factories , chemical and gas-processing industrials.\n\n\n",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"heat transfer devices",
"minimal environmental",
"temperature ambient air",
"heat exchanger cleaning",
"EVAPORATOR COIL COOLING",
"customer specifications",
"Cooling Tower performance",
"Cooling Tower maintenance",
"Enterprises Fin Fan Coolers",
"steel manufacturing industry",
"EVAPORATIVE COIL COOLING TOWER",
"turbine exhaust steam condensation",
"professional Fin Type Coolerand air"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 9,
"imageuri": "https://productimages.withfloats.com/actual/5cc18b12cb2c9d00016b47d3.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/5cc18b12cb2c9d00016b47d3.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2019-04-25T10:25:22.287Z",
"updatedon": "2019-04-25T10:25:22.287Z",
"buyonlinelink": null,
"producturl": "http://WWW.CHILLERCOOLINGTOWER.COM/products/evaporative-coil-cooling-tower/9",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "EVAPORATOR COIL COOLING TOWER",
"tags": [
"EVAPORATOR COIL COOLING TOWER",
"EVAPORATIVE COIL COOLING TOWER"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "None",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5cc18a4f99174d000166cbea",
"fptag": "JANANIENTERPRISES",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "DRY COOLING TOWERS",
"description": "DRY COOLING TOWERS\n\nDry Cooling Towers are produced in forced drought and induced drought designs, and in Single and Multi-Fan Arrangements, Depending on customer specifications and requirements, We are the professional dry Cooling Tower and Air Cooled Condenser Manufacturers, Tubes in Copper and Fins are Aluminium MOC we use 5/8'' or 3/8'' OD copper tubes as per customer specification, all tubes are well expanded tested for pressure and leak.\n\nAdvantages\n\nA great deal of water gets preserved on using dry Cooling Towers.\nLess or no preparation needed as atmospheric air is in abundance\nNo formation of scale or heat exchanger cleaning is required\nThere are no mobile parts except for the fan and the motors. Hence the Cooling Tower maintenance is negligible.\nDust, fly ash, living organisms or dirt do not get mixed up with process water\nThere are no constraints placed on the location of plant\nNo corrosion caused by air\nThis Cooling Tower performance ensures minimal environmental impact\nReduced annual operating expenses\n\nApplications\n\nPredominantly used for air compressor and power generating units for applications of engine water cooling. Petroleum plant, power utility, steel manufacturing industry, cement, sugar factories , chemical and gas-processing industrials.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"air compressor",
"atmospheric air",
"Petroleum plant",
"drought designs",
"annual operating",
"DRY COOLING TOWERS",
"minimal environmental",
"customer specifications",
"heat exchanger cleaning",
"Cooling Tower performance",
"Cooling Tower maintenance",
"steel manufacturing industry",
"professional dry Cooling Tower",
"Air Cooled Condenser Manufacturers"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 8,
"imageuri": "https://productimages.withfloats.com/actual/5cc18a4f8d9e570001008cfb.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/5cc18a4f8d9e570001008cfb.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2019-04-25T10:22:07.139Z",
"updatedon": "2019-04-25T10:22:07.139Z",
"buyonlinelink": null,
"producturl": "http://WWW.CHILLERCOOLINGTOWER.COM//dry-cooling-towers/8",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "DRY COOLING TOWERS",
"tags": [
"DRY COOLING TOWERS"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "None",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5cc189b0d4443e000114a300",
"fptag": "JANANIENTERPRISES",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "TIMBER COOLING TOWER (CROSS / COUNTER FLOW)",
"description": "TIMBER COOLING TOWER (CROSS / COUNTER FLOW)\n\nTimber Cooling Tower (Cross / Counter Flow)\n\nThere are a total of 107 models available under single cell configuration. Multi-cell configurations are provided to offer flexibility of operations and also to meet increased cooling requirements. These Cooling Towers are supplied with treated timber construction, which is pressure treated with Copper Chromate Arsenic. Structural design for operational load and wind pressure of 30 psf. is taken into consideration.\nCCA (copper chromate arsenic) treated timber / wood Cooling Towers have proven themselves the worldover. These timber / wood Cooling Towers are available in induced draft cross flow & induced draft counter flow design. Water handling capacity ranges from 45 M3/hr. to 5000 M3/hr. per cell capacity. Fan diameter varies from 1500 mm to 10000 mm. Different models have different Air Travels, Fill height, Fill pattern, Fan diameter, etc. in cross flow design AND varied Fill height, Fill design, etc. in counter flow design.\n\nFeatures\n Eliminates fill media and hence maintenance\nEliminates motor / fan and hence power consumption\nUsed for high temperature applications\nUsed for industries having polluted waters\nAll structural in HDG Steel, to arrest rust\nAll joints with SS fasteners\nAero dynamic designed FRP / GI louvers",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"Fill design",
"draft cross flow",
"cross flow design",
"Structural design",
"wood Cooling Towers",
"Fan diameter varies",
"TIMBER COOLING TOWER",
"107 models available",
"different Air Travels",
"Eliminates fill media",
"copper chromate arsenic",
"draft counter flow design",
"single cell configuration",
"treated timber construction",
"increased cooling requirements"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 7,
"imageuri": "https://productimages.withfloats.com/actual/5cc189b16754ed00018a49f1.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/5cc189b16754ed00018a49f1.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2019-04-25T10:19:28.922Z",
"updatedon": "2019-04-25T10:19:28.922Z",
"buyonlinelink": null,
"producturl": "http://WWW.CHILLERCOOLINGTOWER.COM//timber-cooling-tower-cross-counter-flow-/7",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "TIMBER COOLING TOWER (CROSS / COUNTER FLOW)",
"tags": [
"TIMBER COOLING TOWER (CROSS / COUNTER FLOW)"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "None",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5cc189352f10160001901054",
"fptag": "JANANIENTERPRISES",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "FANLESS / FILLESS COOLING TOWER",
"description": "FANLESS / FILLESS COOLING TOWER\n\nFanless / Filless Cooling Tower\n\nThe Fanless, Filless Induced Draft design has been developed after a detailed research and analysis of the engineering design. This design allows a substantial saving in Power Consumption. Also, the common problems of breakdown and maintenance of Cooling Tower are eliminated to a large extent with this design.\n\nTechnical Function\n\nThe Hot water from the heat source is circulated to the inlet header of the Cooling Tower. The inlet header pipes have branches and sub branches covering the internal area of the cooling towers. The non clog nozzles are connected at the outlets of the sub branch piping's.\nAt a inlet pressure of 1 - 1.5 Kg/cm2 to the Cooling Tower, the hot waters are atomized to a mist state. The nozzles are self designed to create more pressure thereby converting water into minute atomized particles. From the four sides of the louvers, plenty of fresh air is automatically circulated by the aero dynamic designed FRP louvers. Waters are directed by the special aero dynamic louvers towards the collection sump. The louvers ensure that the water donot spill out of the towers. \nThe hot waters, that are in a mist state, comes directly in to contact with the ambient air and the cooling is achieved mainly by, the portion of water, that gets converted to vapors, thus caring away the latent heat of evaporation. Therefore, water gets cooled and in this process, the air gets heated, saturated and thereby caring away some sensible heat from water.\n\nFeatures\n\n Eliminates fill media and hence maintenance\nEliminates motor / fan and hence power consumption\nUsed for high temperature applications\nUsed for industries having polluted waters\nAll structural in HDG Steel, to arrest rust\nAll joints with SS fasteners\nAero dynamic designed FRP / GI louvers\nCapacities 10TR to 1000TR, in a single cell\nWater flow 10CMH to 1000 CMH, in a single cell",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"FRP louvers",
"sensible heat",
"inlet pressure",
"collection sump",
"high temperature",
"water donot spill",
"Power Consumption",
"detailed research",
"inlet header pipes",
"engineering design",
"FILLESS COOLING TOWER",
"Filless Induced Draft design",
"special aero dynamic louvers towards"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 6,
"imageuri": "https://productimages.withfloats.com/actual/5cc1893566f21f00011e3b34.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/5cc1893566f21f00011e3b34.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2019-04-25T10:17:25.031Z",
"updatedon": "2019-04-25T10:17:25.031Z",
"buyonlinelink": null,
"producturl": "http://WWW.CHILLERCOOLINGTOWER.COM/products/fanless-filless-cooling-tower/6",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "FANLESS / FILLESS COOLING TOWER",
"tags": [
"FANLESS / FILLESS COOLING TOWER"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "None",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5cc186cf2f10160001901025",
"fptag": "JANANIENTERPRISES",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "INDUCED DRAFT COOLING TOWER",
"description": "INDUCED DRAFT COOLING TOWER\n\nCooling water returns in a warm state from the process and enters at the top of the cooling tower under pressure to be distributed through the fill pack. Simultaneously, air is drawn in at the base of the tower by the fan and travels upward to mix with the water where some evaporation takes place, removing heat from the remainder. The warm moist air is discharged to atmosphere.\n\nFeatures\nCooling capacities from 50kW to 12,000kW.\nBody and basin constructed from Z725 galvanized steel.\nHigh performance, long life axial fan.\nVertical air discharge at a sufficient distance from the horizontal air intake to prevent air re-circulation.\nHighly efficient drift eliminator limiting water losses to less than 0.001% of the water re-circulation rate.\nPatented fill pack inducing a highly turbulent mixing of air and water for superior heat transfer.\nSuperior two pass air intake louver and screen design to minimise water splash out and block sunlight to reduce algae formation. The low pressure drop design results in lower fan energy consumption and operating costs.\nPressurized water distribution system with sediment preventing sludge rings incorporated within the spray nozzles. Easily removed for maintenance.\nA.C.O.P L8-2000 compliant.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"prevent air",
"two pass air",
"water losses",
"water returns",
"air discharge",
"warm moist air",
"horizontal air",
"sufficient distance",
"minimise water splash",
"fan energy consumption",
"water distribution system",
"efficient drift eliminator",
"INDUCED DRAFT COOLING TOWER",
"low pressure drop design results"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 3,
"imageuri": "https://productimages.withfloats.com/actual/5cc186cfe61a030001e6f797.jpg",
"tileimageuri": "https://productimages.withfloats.com/tile/5cc186cfe61a030001e6f797.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2019-04-25T10:07:11.272Z",
"updatedon": "2019-04-25T10:07:11.272Z",
"buyonlinelink": null,
"producturl": "http://WWW.CHILLERCOOLINGTOWER.COM/products/induced-draft-cooling-tower/3",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "INDUCED DRAFT COOLING TOWER",
"tags": [
"INDUCED DRAFT COOLING TOWER"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "None",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
}
],
"hasmoreitems": false,
"isapirequest": false,
"totalresults": 27,
"query": null,
"floatingpoint": null
}